Full Version: Epilog 24TT 45watt

From: jeff (JCHUMBLEY) [#5]
 31 Mar 2007
To: Harvey only (HARVEY-ONLY) [#4] 1 Apr 2007

I understand the issue that could be caused by ramping but............

This is a repeat customer for me and last time I ran this file/job there was no problems at all

I have a template that has 10 across and 5 down. The last time I ran the job everything worked fine, but today all I can get to work is taking the first and last rows off.

Don't know what to do at this point cuz its the weekend.


From: Harvey only (HARVEY-ONLY) [#6]
 1 Apr 2007
To: jeff (JCHUMBLEY) [#5] 1 Apr 2007

Lasers do change over time, usually not a short time though.

I have heard of that when the tickle adjustment needs alterations. Maybe due to loss of tube gas. But a week or two would be the first time I have heard of such a short time. Try calling their service department and see if they have any ideas.

In the meantime leaving off the end rows keeps you in business.


From: jeff (JCHUMBLEY) [#7]
 1 Apr 2007
To: Harvey only (HARVEY-ONLY) [#6] 1 Apr 2007

Leaving off the ends did keep me in business. 456 pieces later I'm done. I hope its not that tube I just replaced that bout 4 months ago!!

Show messages: All  1-4  5-7